FDA requires a unique device identifier on the label of every medical device, and the EU deadline to register devices already on the market in EUDAMED is November 28, 2026. This guide shows what the UDI must hold, how the GTIN and lot fit in one GS1 code, and how to recall a single lot from the scan.
DLCode · Updated · 8 min read
What FDA's UDI rule requires
Under 21 CFR 801.20, the label of every medical device must bear a unique device identifier (UDI), and so must every device package.
21 CFR 830.3 defines the UDI in two parts. The device identifier is the fixed part that identifies the version or model of the device. The production identifier is the variable part that carries the lot or batch, serial number, expiration date or manufacturing date when the label shows them.
Under 21 CFR 801.40, the UDI must appear in two forms on the label: easily readable plain text, and automatic identification and data capture (AIDC) technology such as a barcode. If the label includes a lot number or an expiration date, the UDI must include them too. If the AIDC is not visible on the label, the label must say it is there.
Under 21 CFR 830.20, the UDI must be issued under a system run by FDA or an FDA-accredited issuing agency. FDA lists three accredited agencies, and GS1 is one of them. With GS1, the device identifier is your GTIN.
GUDID: the record behind every UDI
Under 21 CFR 830.300, the labeler must submit information about each version or model that bears a UDI to FDA's Global Unique Device Identification Database (GUDID). You submit through the GUDID web application, one device at a time, or in bulk as HL7 SPL files through the FDA Electronic Submissions Gateway.
Under 21 CFR 830.330, the first submission is due no later than the date the label must bear the UDI. When information on the label changes, the update is due by the date you first label a device with it. Other changes are due within 10 business days.
FDA said it did not intend to enforce GUDID submissions for most class I and unclassified devices before December 8, 2022. That date has passed, so put the UDI on the label and the record in GUDID for the devices you ship today. Anyone can look up that record in AccessGUDID, FDA's public search of device identification data.
EU MDR: UDI and the November 28, 2026 EUDAMED deadline
Under Article 27 of the EU Medical Device Regulation, a device carries a UDI made of a UDI-DI, specific to the manufacturer and the device, and a UDI-PI, which identifies the unit of production. Manufacturers also assign a Basic UDI-DI, the main key in the EU database and related documents.
The European Commission designates four issuing entities for UDIs, and GS1 is one of them. The same GS1 GTIN can serve as your device identifier in the US and the EU.
Mandatory use of the EUDAMED UDI/Device registration module began on May 28, 2026. A new device placed on the EU market since then must be registered before its first unit ships. Devices already on the market before May 28, 2026 must be registered by November 28, 2026.
If you ship to Europe, that deadline is 15 days away. The Basic UDI-DI is the main key in the database, so confirm your GTINs now.
Lots and recalls
Under 21 CFR 806.10, a device manufacturer or importer must report a correction or removal to FDA within 10 working days of starting it, when the action reduces a risk to health. The report must include the UDI on the device label or package, the total number of devices subject to the action and the number in the same lot.
FDA lists the most serious device recalls on its Medical Device Recalls and Early Alerts page. It also posts early alerts about corrective actions it believes are likely to be among the most serious.
A recall moves faster when every unit tells you its lot. The lot already sits in the production identifier of your UDI. Put the same lot in a code that a phone can scan, and the scan can show the right notice for the unit in hand.
How GS1 codes carry your UDI
GS1 Application Identifier 01 is the GTIN, 10 is the batch or lot number and 17 is the expiration date. In its example of a device label, GS1 Sweden says GS1-128 or GS1 DataMatrix should be used in place of an EAN-13 barcode. It recommends GS1 DataMatrix, because GS1-128 may need two lines, which is hard to scan in healthcare.
DLCode makes a GS1 DataMatrix file that carries AI 01, 17 and 10, the GTIN, expiry and lot of your UDI. Print it next to the plain-text UDI on the label.
DLCode also makes a GS1 Digital Link QR code. It is a web address that holds the same GTIN, with the lot in the path after /10/ and the expiry in the query after ?17= in YYMMDD form.
https://qr.yourdevice.com/01/00850012345671/10/A2611?17=290531A patient or clinician who scans the QR code with a phone opens the page you choose. On a paid pack or the trial, you can add GS1 link types such as instructions, safetyInfo and support, and limit any link to one lot. A scan of lot A2611 then opens the page for lot A2611.
Use your own domain, such as qr.yourdevice.com, in the code. The printed address belongs to your company, and you can change where it sends scans at any time without a reprint. See Use your own domain for GS1 QR codes.
Recall one lot from the scan
In DLCode, you can mark a whole product as recalled. You can also mark only listed lots, or every lot that expires on or before a date. Starting a recall needs a paid pack or the trial. Ending a recall works on every plan.
Scans of an affected lot open the hosted page with your recall notice. Scans of other lots keep opening your normal link. The GS1 linkset for the product reports the recall status, and every change is written to the product's recall history.
Pair the scan notice with the report you file with FDA and the notices you send to distributors and customers. For the full steps, see How to tell customers which batch is recalled.
Printing a code for each lot
Each lot gets its own code because the lot is part of the data. Lot files need a paid pack or the trial.
- Pre-printed labels and pouches: download the lot's QR code as SVG, PDF, EPS or 600 dpi PNG, or the GS1 DataMatrix file, and send it to your printer.
- Label software such as BarTender or NiceLabel: build the QR address in the template with the pattern https://{your domain}/01/{GTIN-14}/10/{lot}?17={YYMMDD}.
- Automated files: request GET /api/v1/products/{gtin}/qr.svg?lot=A2611&expiry=2029-05-31 with your API key. PDF and EPS are also available.
Lot codes can be up to 20 characters from the GS1 character set. Use the same lot text that appears in the plain-text UDI.
On paid packs and the trial, import a lot CSV of up to 5,000 rows with columns such as gtin, lot, expiry, packed_on and quantity. Each lot record stores the expiry, pack date and quantity, and you can export every lot as a CSV.
The QR module is 0.495 mm by default with a 4-module quiet zone. See Print specs for a QR code next to your UPC or EAN.
Devices sold in retail stores
If your device sells in drugstores or other retail stores, the register matters too. GS1 US describes Sunrise 2027 as a global move from 1D UPC barcodes to 2D barcodes such as QR codes, with retailers preparing point-of-sale systems to read them. A GS1 Digital Link QR code holds your GTIN, so the same code can ring up at those registers. See Sunrise 2027 for sizes and placement, and DLCode for retail brands.
What it costs
Each GTIN counts as one product in DLCode. Lots do not count toward the product limit.
| Plan | Price | Products | Lot links and lot recalls |
|---|---|---|---|
| Free | $0 | 10 | No |
| 25 products | $249 one time | 25 | Yes |
| 100 products | $499 one time | 100 | Yes |
| 1,000 products | $1,490 one time | 1,000 | Yes |
Each pack covers hosting and unlimited scans through December 31, 2030, with no subscription. After that, hosting is $29 per year. The 30-day trial includes the paid features for up to 25 products, with no card. See pricing.
What to do this month
- Confirm each device version or model has its own GTIN from GS1. See How to get a GTIN.
- Check that every GTIN has a current record in GUDID.
- If you sell in the EU, register each device already on the market in the EUDAMED UDI/Device module by November 28, 2026.
- List the production identifiers your label shows, such as lot and expiry, and make sure the UDI carries each one.
- Decide which page a scan of each lot should open, such as instructions, safety information or support.
- Connect a domain you control, such as qr.yourdevice.com, before you print.
- Add the lot's code to your next label run, then scan a proof with an iPhone and an Android phone.
- Write your recall notice text now, and test a lot recall before you need one.
Have every lot one scan from the right notice
Set up one device, add your lots, and have a recall ready before you ever need it.
- Each lot gets its own code with the GTIN, lot and expiry of your UDI.
- Download a GS1 DataMatrix file or a GS1 QR code for each lot.
- Send each lot's scans to its own instructions, safety or support page.
- Recall listed lots, or every lot that expires on or before a date.
- Import up to 5,000 lots from a CSV and export them any time.
- Use your own domain so every code carries your brand.
Start free for 10 products, with no card. When you need more, pay once from $249 for 25 products. Hosting and unlimited scans are included through December 31, 2030, with no subscription. New accounts get lot links and recalls free for 30 days on up to 25 products.
Make the code for your next label run today. Start free or See pricing.
Sources
- 21 CFR 801.20: Label to bear a unique device identifier · Legal Information Institute, Cornell Law School
- 21 CFR 801.40: Form of a unique device identifier · Legal Information Institute, Cornell Law School
- 21 CFR 801.45: Devices that must be directly marked with a unique device identifier · Legal Information Institute, Cornell Law School
- 21 CFR 830.3: Definitions · Legal Information Institute, Cornell Law School
- 21 CFR 830.20: Requirements for a unique device identifier · Legal Information Institute, Cornell Law School
- 21 CFR 830.300: Devices subject to device identification data submission requirements · Legal Information Institute, Cornell Law School
- 21 CFR 830.330: Times for submission of unique device identification information · Legal Information Institute, Cornell Law School
- 21 CFR 806.10: Reports of corrections and removals · Legal Information Institute, Cornell Law School
- Unique Device Identification System (UDI System) · U.S. Food and Drug Administration
- Contact an FDA-Accredited Issuing Agency · U.S. Food and Drug Administration
- Medical Device Recalls and Early Alerts · U.S. Food and Drug Administration
- Unique Device Identifier (UDI) · European Commission
- Mandatory use of EUDAMED modules for medical devices · Health Products Regulatory Authority (Ireland)
- UDI: Unique Device Identification · GS1 Sweden
- What is GS1 Sunrise 2027? · GS1 US
- GS1 Digital Link URI syntax · GS1
- GS1 Application Identifier (01): Global Trade Item Number · GS1
- GS1 Application Identifier (10): Batch or lot number · GS1
- GS1 Application Identifier (17): Expiration date · GS1